Customization: | Available |
---|---|
Certification: | ISO, ASME, API |
Application: | Heater, Cooler, Vaporizer, Condenser |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Medium | Gas to Gas, Liquid to Liquid, Gas to Liquid, |
Design Temperature: | Max. 350ºC |
Design pressure | Max. 3.2 MPa |
Plate type | Heat Efficiency type, wide channel type |
Plate Material: | 304,316L,AL-6XN,Hastel loy C-276,254MO,nickel, nickel base alloy |
Design Pressure | WT1.6/2.5/4.0/6.3MPa |
Maximum Pressure | 9.8 MPa |
Design Temperature | -100-450ºC |
Maximum design Temperature | -196-700ºC |
heat exchanger | 0.5-280 m2 |
minimum heat transfer temperature difference | <2ºC |
Compact structure | the unit volume of the heat transfer area: 300m2/m3 ordinary tube heat exchanger: 80-140m2/m3 |
More uptime and longer life due to greater fatigue resistance |
Higher operating pressures thanks to robust, patented construction |
Operational gains created by 15-20% higher thermal efficiency |
Installation savings through even more compact, lightweight design |
small scaling rate,extremely low maintenance cost |
various materials are available |